High pressure valve

Hydrogen Piping Test Unit


Drive air supply: 1~8bar;Output pressure: 200-1150 bar;


Key Features
  • Key Features
  • Dimensional Drawing

Standard configuration list


Name/ModelQuantity
Air box1
Boost pump 2GBF80/1501
Inlet high-pressure hose1
Outlet high-pressure hose1
Adapter4


Product Parameter


ModelBoost ratioMinimum gas
inlet pressure
Pi(bar)
Maximum allowable
outlet pressure
Po(bar)
Calculation formula
of gas outlet pressure
Po=
Gas inlet INGas outlet OUTMaximum flow
standard L/min
(NL/Min)
Weight(kg)A(mm)B(mm)C(mm)
2GBF80-150150:1451245150pa+3pi1/4"NPTG1/4External thread
+60°cone
42027895290345




Functional Characteristics


2GBF80/150 hydrogen pipeline test unit is a power unit specially designed for domestic hydrogen pipelines, which is used for high pressure pipeline field valve, pipeline and joint high pressure inspection and test.


Equipment structure


Installation cabinet of gas boosting system adopts highly integrated structure. Considering the requirements of convenient operation and convenient transportation, valves are placed on the external operating panel, pipe connections are set on the left and right sides, and pneumatic pumps and filters are installed internally to facilitate installation, maintenance and repair.

Structure Dimension Diagram

2GBF-150氢气管道测试单元.jpg

Copyright © 2012-2021 Shenzhen Siteke Pneumatic Hydraulic Co., Ltd. Copyright         粤ICP备15051776号

0755-27967320

Siteke