Liquid Pumps
Position : Home > Products > Liquid Pumps

Air Driven Liquid Pump of AT Series

Maximum output pressure: 33.2MPa;Boost ratio: 1:4;Working medium: non corrosive liquid;Driving medium: compressed air;The pressure range of drive air inlet is 0.1-0.83MPa (for the sake of product service life, it is recommended that the drive air inlet pressure be 0.7MPa);Maximum air consumption based on 0.7MPa driving air pressure: 1m ³/ min;Displacement per stroke: 401.2ML;Low pressure medium inlet connector size: PT3/4 ";High pressure medium outlet connector size: PT3/4 ".


Key Features
  • Key Features
  • Specification

Product Parameter


Air Driven Liquid Pump of AT Series
Based on static pressure, the air consumption is 1.0m³ when the air pressure is 7Bar.  
ModelPiston/Rod DiameterΦ ( mm)Flow per stroke( ml)INOUTMax gas outlet Po (bar)@drive  8.3barOutput liquid Po(bar)  1bar=0.1MPa=1.019Kg/cm²
0204070100150200300400500600700900120017002350
Flow(L/min)
AT0480401.92PT3/4"PT3/4"33.2















AT0763249.25PT3/4"PT3/4"58.1















AT1050235.5PT3/4"PT3/4"83















AT1640188.5PT3/4"PT3/4"132.822.621713.211.34.71










AT2035144.32PT3/4"PT3/4"16617.3214.4312.9911.5510.10









AT2830106.03PT1/2"PT1/2"232.412.7210.69.548.487.426.360








AT402573.63PT1/2"PT1/2"3328.847.366.635.895.154.423.680







AT642047.12PT3/8"NPT3/8"4985.654.714.243.773.32.832.361.881.41






AT801838.17PT3/8"NPT3/8"6644.583.823.443.052.672.291.911.531.341.15





AT1001630.16PT3/8"NPT3/8"8303.623.323.022.872.562.261.811.511.211.060.90



AT1301423.09PT3/8"NPT3/8"10792.772.662.542.312.081.851.621.391.150.920.810.690.23


AT1701212.44PT3/8"NPT3/8"14111.491.431.371.311.241.1210.870.750.620.50.440.370.12

AT240108.64PT3/8"※HF419921.040.990.950.910.860.780.690.60.520.430.350.30.260.220.17
AT30097NPT1/4"※HF424900.840.810.810.770.740.70.630.560.490.420.350.320.280.320.18
AT40085.53NPT1/4"※HF433200.660.640.640.610.580.550.50.440.390.330.280.250.220.210.190.14


Installation Dimensions/(mm)
ModelDrive gas interface
(AIR IN)
ABCDEFGHMounting HoleWeight/kg
AT04G1/2"575.8218178.894240172100/4-φ12*2222
AT07G1/2"53821816094240172100/4-φ12*2219
AT10G1/2"542218162942401721003204-φ12*2220
AT16G1/2"453218115942401721003204-φ12*2223
AT20G1/2"458218120942401721003204-φ12*2223
AT28G1/2"424218103942401721003204-φ12*2218
AT40G1/2"424218103942401721003204-φ12*2218
AT64G1/2"424218103942401721002904-φ12*2218
AT80G1/2"438218110942401721002804-φ12*2218
AT100G1/2"438218110942401721002804-φ12*2218
AT130G1/2"438218110942401721003204-φ12*2218
AT170G1/2"37020881942401721003204-φ12*2218
AT240G1/2"37020881942401721003204-φ12*2217
AT300G1/2"37020881942401721003204-φ12*2217
AT400G1/2"37020881942401721003204-φ12*2217




AT series gas-liquid booster pump is a single-drive double-acting liquid booster pump with compressed air, which has the advantages of high safety, high output pressure and larger flow.

Features


1. The output pressure can reach up to 3320bar, and the output flow is larger than that of the AH series under the same pressure ratio;
2. The gas drive ensures that the medium does not generate heat, sparks and flames during the transmission process, and the pressurization is safe;
3. The driving gas pipeline does not need to be lubricated, which saves costs and prevents pollution;
4. It is suitable for most liquids and liquefied gases, and can maintain pressure without energy consumption at a predetermined pressure, automatically absorb liquid, automatically maintain pressure, and automatically replenish pressure;
5. The product has compact structure, strong reliability and application fields;

Main features


1. AT series is based on static pressure, when the driving air pressure is 7bar, the air consumption is 1.0m3/min;
2. The driving pressure is 1bar-8.3bar (14.5-120.35psi), and the AT series is a single driving piston (Φ160mm)
3. The high-pressure end is made of stainless steel, and the driving part is made of aluminum alloy;
4. The medium of AT series standard products is water and oil, and the order code is: AT64 (series code + boost ratio)
Description of special products:
About medium: AT series can be applied to various media such as brake fluid and liquefied gas, order code such as: AT20-CO2(series code + boost ratio + boost medium)
About the interface: If you need a special interface, please specify when ordering.

Application scenarios


1. AT series gas-liquid booster pump is suitable for occasions with high output pressure and flow requirements;
2. Hydraulic test/burst test (including but not limited to valves, pressure vessels, pressure switches, hoses, BOPs and other pressurized components;
3. Boosting of vehicle braking system;
4. Calibration of pressure gauges and sensors;
5. Water jet for cutting and cleaning;
6. Leak test, oil and gas well shutdown system;
7. Operation and control of wellhead equipment;
8. Lifting of hydraulic lifting structure;

Copyright © 2012-2021 Shenzhen Siteke Pneumatic Hydraulic Co., Ltd. Copyright         粤ICP备15051776号

0755-27967320

Siteke